Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
J Dent (Shiraz) ; 25(1): 59-67, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38544779

RESUMO

Statement of the Problem: Periodontitis is an inflammatory disease that causes bone loss. Some patients do not respond well to the classic treatment and need therapies that minimize bone loss, the main sequel of the disease. Chenopodium ambrosioides L. has stood out due to its anti-inflammatory and anti-oxidative activities. However, no study has yet investigated its effect on periodontitis. Purpose: This study aimed to evaluate the bone protective effect of Chenopodium ambrosioides L. (CAL) extract on ligature-induced periodontitis model in rats. Materials and Method: For this, a pre-clinical assay was performed, using male Wistar rats divided into 3 groups: Naive (N) (n=6), not submitted to any procedure; Saline (SAL) (n=6), submitted to ligature-induced periodontitis and receiving 2 ml/kg of 0.9% saline solution; and CAL extract, which was subdivided into 3 subgroups (n=6/subgroup) receiving the CAL at 3 (CAL3), 10 (CAL10) or 30 mg/kg (CAL30). All agents were given, by oral gavage, 30 min before periodontitis induction and daily until euthanasia (11th day). By then, maxillae were removed for macroscopic, histological, and histometric analyses. Kidneys, liver, and stomach were collected to evaluate the safety of CAL extract. High-performance liquid chromatography (HPLC) assay was used to investigate the flavonoid content in the extract. Results: Chenopodium ambrosioides L. extract at 30mg/kg showed a reduction by 58% in bone loss marked by an increase (+35%) in the number of osteoblasts and a reduction (-51%) on the number of osteoclasts (p< 0.05). No significant alteration in the liver, kidney, or stomach was seen. Rutin was the main flavonoid found. Conclusion: In summary, it was observed that Chenopodium ambrosioides L. extract has shown important anti-inflammatory and bone anabolic and anti-resorptive properties without causing toxicity in the main organs. Rutin, as the main flavonoid of the extract, seems to be responsible for the beneficial effect of this agent.

2.
Clin Oral Investig ; 27(11): 6413-6420, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37704914

RESUMO

AIM: To assess the observed volume of filled C-shaped root canals from different CBCT and micro-CT having nano-CT as a reference. MATERIALS AND METHODS: Twelve extracted mandibular molars with C-shaped root canals were endodontically treated using Reciproc Blue R25 (VDW GMBH, Munich, Germany) in a reciprocating system and filled with gutta-percha (Dentsply Maillefer) and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany). CBCT scans were performed using 3 units-3D Accuitomo 170 (J. Morita, Kyoto, Japan), ProMax 3D Max (Planmeca, Helsinki, Finland), and NewTom VGi EVO (Cefla QR, Verona, Italy)-at two resolution modes: standard and high. Micro-CT and nano-CT scans were also obtained. The volume of all filled C-shaped root canals was obtained using CTAn software (Bruker, Kontich, Belgium), and the blooming artifact, in relation to nano-CT volume, was calculated. The data were evaluated by the Bland-Altman plots and ANOVA two-way for repeated measures (α = 0.05). RESULTS: All CBCT units and micro-CT showed significantly larger observed volume of root canal filling when compared to nano-CT. The blooming artifact of root canal filling in standard resolution was significantly larger than that in high resolution (p < 0.05) in all CBCT units. CONCLUSIONS: Endodontic filling material with AH Plus sealer causes blooming artifacts in CBCT units and micro-CT. CLINICAL RELEVANCE: Considering the anatomical complexity of C-shaped root canals and the challenges associated with endodontic treatment, CBCT is frequently recommended for follow-up evaluations. However, the presence of endodontic filling material can result in blooming artifacts that may potentially impact the accurate diagnosis of endodontic complications.


Assuntos
Materiais Restauradores do Canal Radicular , Cavidade Pulpar , Microtomografia por Raio-X , Preparo de Canal Radicular , Retratamento , Guta-Percha , Obturação do Canal Radicular , Tomografia Computadorizada de Feixe Cônico
3.
Dentomaxillofac Radiol ; 52(6): 20230072, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37606052

RESUMO

OBJECTIVES: To investigate whether variations in head positioning may influence the reproducibility of cone-beam CT (CBCT) three-dimensional (3D) segmented models of the mandibular condyle. METHODS: Five fresh frozen cadaver heads were scanned in four different positions: reference position (RP) and a set of three tilted alternative head positions (AP) in anteroposterior direction (AP1: 2 cm anterior translation, AP2: 5° pitch rotation, AP3: 10° pitch rotation). Surface models of mandibular condyles were constructed and compared with the condylar reference position using voxel-based registration. Descriptive statistics and a linear mixed-effects model were performed to compare condylar volumetric differences and root mean square (RMS) distance between surfaces of AP vs RP. RESULTS: The mean differences in condylar volumes of AP vs RP were 14.1 mm³ (95% CI [-79.3, 107.4]) for AP1, 1.0 mm³ (95% CI [-87.2, 89.2]) for AP2 and 0.1 mm³ (95% CI [-88.3, 88.4]) for AP3. Mean and absolute volumetric differences did not exceed earlier reported intraoperator differences of 30 mm³. The RMS distance values obtained per group were 0.12 mm (95% CI [0.05,0.20]) for AP1, 0.17 mm (95% CI [0.10, 0.22]) for AP2 and 0.17 mm for AP3 (95% CI [0.10,0.22]). The confidence intervals (CI) for RMS distance remained far below the threshold for clinical acceptability (0.5 mm). CONCLUSIONS: Within the limits of the present study, it is suggested that tilted head positions may affect the reproducibility of 3D condylar segmentation, thereby influencing outcome in repeated CBCT scanning. Nevertheless, observed differences are unlikely to have a meaningful impact on clinical patient diagnosis and management.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Reprodutibilidade dos Testes , Cadáver , Tomografia Computadorizada de Feixe Cônico , Côndilo Mandibular/diagnóstico por imagem
4.
Braz Oral Res ; 37: e059, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37341232

RESUMO

The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Período Pós-Operatório
5.
Sci Rep ; 13(1): 6266, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-37069172

RESUMO

Photon-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device. Thereafter, the phantom was scanned with three imaging devices, which included PCCT scanner (NAEOTOM Alpha) and two CBCT devices (3D Accuitomo 170 and NewTom VGi evo) having standard and high-resolution acquisition protocols. The diagnostic tasks involved visualizing fine endodontic structures (apical delta, narrow canal, and isthmus) and root cracks. Three experienced examiners assessed the images and were blinded to the PCCT and CBCT devices. Each image was rated according to a three-grade scale (appropriate, acceptable, or inappropriate) for the diagnostic tasks. In relation to fine endodontic structures grouped together, PCCT showed similar diagnostic performance compared to the reference image (p > 0.05). As for the CBCT devices, an excellent performance was only observed with the 3D Accuitomo 170 device at a high-resolution acquisition mode (p > 0.05). The visualization of root cracks was also better with 3D Accuitomo 170 compared to other devices (p < 0.05). Overall, PCCT and 3D Accuitomo 170 at a high-resolution setting showed similar performance for visualizing fine endodontic structures. In addition, the high-resolution CBCT protocol was superior for visualizing root cracks compared to both PCCT and other standard- and high-resolution CBCT protocols.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Microtomografia por Raio-X , Imagens de Fantasmas
6.
Sci Rep ; 13(1): 4001, 2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36899046

RESUMO

The aim of this study was to evaluate CBCT exposure protocols and CBCT devices in terms of image quality for the detection of cracks and fine endodontic structures using 3 conditions of metallic artifacts. An anthropomorphic phantom containing teeth with cracks, isthmus, narrow canal, and apical delta was scanned using ten CBCT devices. A reference industrial CT image was used to detect and measure all structures. Three conditions were created: (1) metal-free, (2) 'endo' and (3) 'implant' with metallic objects placed next to the teeth of interest. For each condition, three protocols were selected: medium field of view (FOV) standard resolution, small FOV standard and high resolution. The results showed that only small FOV high-resolution metal-free images from two devices (A and H) were appropriate to visualize cracks. For fine structure identification, the best result was observed for small FOV high resolution. However, the visualization significantly worsened in the presence of metallic artefacts. The ability of CBCT images for visualizing cracks is restricted to certain CBCT devices. Once metallic artefacts are present, crack detection becomes unlikely. Overall, small FOV high-resolution protocols may allow detection of fine endodontic structures as long as there are no high-dense objects in the region of interest.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico/métodos , Artefatos , Cintilografia , Imagens de Fantasmas , Metais
7.
Br J Nutr ; 130(10): 1779-1786, 2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-36938805

RESUMO

The final stage of Fe deficiency is Fe deficiency anaemia, with repercussions for human health, especially in children under 5 years of age. Studies conducted in Brazilian public daycare centres show high prevalence of anaemia. The present study aims to evaluate the availability of Fe in the meals of the Municipal Centers of Early Childhood Education in Maceió. The experimental design comprises selection of algorithms, menu evaluation, calculation of the estimates, comparison between the estimates obtained and the recommendations, and analysis of correlation between meal constituents, and of the concordance between the absorbable Fe estimates. Four algorithms were selected and a monthly menu consisting of 22 d. The correlation analysis showed a moderate positive correlation to animal tissue (AT) v. non-heme iron (r = 0·42; P = 0·04), and negative to AT v. Ca (r = -0·54; P = 0·09) and Ca v. phytates (r = -0·46, P = 0·03). Estimates of absorbable Fe ranged from 0·23 to 0·44 mg/d. The amount of Fe available, unlike the total amount of Fe offered, does not meet the nutritional recommendations on most school days. The Bland-Altman analysis indicated that the Monsen and Balinfty and Rickard et al. showed greater agreement. The results confirm the need to adopt strategies to increase the availability of Fe in school meals.


Assuntos
Anemia Ferropriva , Ferro , Criança , Animais , Humanos , Pré-Escolar , Brasil/epidemiologia , Anemia Ferropriva/epidemiologia , Refeições
8.
Sci Rep ; 13(1): 4881, 2023 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-36966188

RESUMO

The aim of this study was to evaluate the foraminal enlargement and its influence on microcrack formation and apical transportation in root canals with apical curvature. Eighteen maxillary lateral incisors with apical curvature were selected by using micro-CT images. Root canals were randomly divided in two groups (n = 9) according to root canal preparation using two working lengths: 1 mm short of the apical foramen (control group) and 1 mm beyond the apical foramen (foraminal enlargement). For both groups Reciproc Blue R40 was used for root canal instrumentation. Specimens were scanned by nano-CT (UniTOM HR) before and after root canal preparation. Percentage, length, and width of microcracks, and apical transportation were assessed. Kappa, chi-square and McNemar tests were used for qualitative analyses while paired and unpaired t-test were used for quantitative analyses (α = 0.05). For both groups, rather similar and low percentages of microcracks were observed before root canal preparation (P > 0.05). The foraminal enlargement promoted new microcracks, not observed in the control group. An increase in microcrack length was observed when the foraminal enlargement was performed (P < 0.05). Higher apical transportation was observed when foraminal enlargement was performed (P < 0.05). Foraminal enlargement using a heat-treated reciprocating file size 40 promoted microcracks and higher apical transportation than root canal preparation up to 1 mm short of apical foramen.


Assuntos
Preparo de Canal Radicular , Ápice Dentário , Temperatura Alta , Ápice Dentário/diagnóstico por imagem , Microtomografia por Raio-X , Humanos
9.
Support Care Cancer ; 31(2): 149, 2023 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-36737557

RESUMO

PURPOSE: To assess radiographic presentation of anatomical structures, bony changes and soft tissue calcifications on panoramic radiographs of oncologic patients under high dose antiresorptive drug therapy (ART) before exposure to dental extraction. METHODS: Panoramic radiographs of 57 patients under ART, taken previously to tooth extraction, and 57 control patients were evaluated by two oral radiologists regarding bone pattern, anatomical structures visibility, estimation of cortical width, mandibular cortical index (MCI), and presence of soft tissue calcifications. Parameters were compared between ART and age- and gender-matched healthy control groups. Bone patterns were further assessed by regions with or without tooth extractions and according to uneventful healing or MRONJ development. All comparisons were made using chi-square test with significance level set at 5%. RESULTS: Mandible and posterior maxilla presented more sclerotic bone patterns in patients under ART, regardless of tooth extraction and MRONJ development status (p < 0.05). Heterogeneous bone pattern was identified in two regions that both were subsequently affected by MRONJ. Anatomical structure visibility and presence of soft tissue calcifications was not different among groups (p > 0.05). ART patients showed significantly more C0 (thickening) and C1 MCI (p < 0.05). CONCLUSION: Sclerotic bone pattern and thicker mandibular cortices may represent a consequence of ART rather than MRONJ specific findings. Prospective studies on larger patient samples radiographically followed-up during the ART treatment are advised, with specific attention to heterogenous trabecular bone pattern as a possible MRONJ predictor.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Humanos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/tratamento farmacológico , Estudos Prospectivos , Percepção , Conservadores da Densidade Óssea/uso terapêutico
10.
Braz. oral res. (Online) ; 37: e059, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439753

RESUMO

Abstract The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.

11.
Distúrb. comun ; 34(4): 55643, dez. 2022. tab, ilus, graf
Artigo em Português | LILACS | ID: biblio-1425483

RESUMO

Introdução: Os termos 'e-audiologia', 'teleaudiologia', 'teleprática em audiologia' e variações, possuem uma característica em comum: avanços tecnológicos na audiologia. Objetivo: O estudo busca avaliar a evolução e desdobramentos da audiologia em modelo remoto no Brasil em comparação a outros países, assim como as vantagens e adversidades proporcionadas por este modelo. Método: Uma revisão integrativa foi realizada por meio de busca e análise de publicações disponíveis nas bases de dados Taylor & Francis Online, PubMed, Scielo, Thieme, ASHAWire e Academia.edu, entre novembro de 2020 e fevereiro de 2021, nos idiomas português brasileiro e inglês. Os termos de busca foram: e-audiologia, e-audiology, teleaudiologia, teleaudiology, telessaúde em audiologia, telehealth in audiology, teleprática em audiologia, telepractice in audiology. Foram considerados artigos publicados de forma gratuita abordando a audiologia em modelo remoto, sem limites ao ano de publicação. Resultados: Foram encontrados 987 artigos, mas apenas 79 foram selecionados para análise na presente revisão. O número de publicações apresentou um aumento nos últimos 5 anos e o Brasil, em comparação a outros países, mostrou bom nível de desenvolvimento em pesquisas na área da teleaudiologia. Conclusão: Não há dúvidas de que a teleaudiologia já possui um impacto significativo e positivo como modelo de atuação audiológica e, assim como em toda evolução, a e-audiologia vem oferecendo, ainda, maiores oportunidades para seus usuários. A insegurança e a incerteza vêm perdendo espaço para pesquisas e atualizações no campo ao redor do mundo, e, mesmo com algumas barreiras a serem enfrentadas, seu crescimento tem possibilitado acesso, autonomia, economia financeira e qualidade.


Introduction: The terms 'e-audiology', 'teleaudiology', 'telepractice in audiology' and variations, have one feature in common: technological advances in audiology. Objective: The study seeks to evaluate the evolution and developments of audiology in a remote model in Brazil compared to other countries, as well as the advantages and adversities provided by this model. Method: An integrative review was carried out by searching and analyzing publications available in the databases: Taylor & Francis Online, PubMed, Scielo, Thieme, ASHAWire and Academia.edu, between November 2020 and February 2021, in Brazilian Portuguese and English. The search words were: e-audiologia, e-audiology, teleaudiologia, teleaudiology, telessaúde em audiologia, telehealth in audiology, teleprática em audiologia, telepractice in audiology. Articles published free of charge addressing audiology in a remote model were considered without limits to the year of publication. Results: 987 articles were found, but only 79 were selected for analysis in this review. The number of publications has increased over the past 5 years and Brazil, compared to other countries, has shown a good level of development in research in the field of teleaudiology. Conclusion: There is no doubt that teleaudiology already has a significant and positive impact as a model of audiological performance and, as in all evolution, e-audiology has been offering even greater opportunities for its users. Insecurity and uncertainty have been losing ground for research and updates in the field around the world and even with some barriers to be faced, their growth has enabled access, autonomy, financial savings and quality.


Introduccíon: Los términos "e-audiología", "teleaudiología", "telepráctica en audiología" y variaciones tienen una característica en común: los avances tecnológicos en audiología. Objetivo: El estudio busca evaluar la evolución y desarrollos de la audiología en un modelo remoto en Brasil en comparación con otros países, así como las ventajas y adversidades que brinda este modelo. Método: Se realizó una revisión integradora mediante la búsqueda y análisis de publicaciones disponibles en las bases de datos Taylor & Francis Online, PubMed, Scielo, Thieme, ASHAWire y Academia.edu, entre noviembre de 2020 y febrero de 2021, en portugués brasileño e inglés. Los términos de búsqueda fueron: e-audiologia, e-audiology, teleaudiologia, teleaudiology, telessaúde em audiologia, telehealth in audiology, teleprática em audiologia, telepractice in audiology. Se consideraron los artículos publicados gratuitamente que abordan la audiología en un modelo remoto, sin límite de año de publicación. Resultado: Se encontraron 987 artículos, pero solo se seleccionaron 79 para el análisis en esta revisión. El número de publicaciones ha aumentado en los últimos 5 años y Brasil, en comparación con otros países, ha mostrado un buen nivel de desarrollo en la investigación en el campo de la teleaudiología. Conclusión: No cabe duda de que la teleaudiología ya tiene un impacto significativo y positivo como modelo de rendimiento audiológico y, como en toda evolución, la e-audiología viene ofreciendo aún mayores oportunidades para sus usuarios. La inseguridad y la incertidumbre han ido perdiendo terreno para las investigaciones y actualizaciones en el campo en todo el mundo, e incluso con algunas barreras que enfrentar, su crecimiento ha permitido el acceso, la autonomía, el ahorro financiero y la calidad.


Assuntos
Audiologia , Telemedicina , Brasil
12.
Clin Oral Implants Res ; 33(12): 1199-1211, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36189488

RESUMO

AIM: To assess, in vitro, variables potentially influencing implant blooming using a human-like imaging phantom and 3D-printed mandibles. MATERIAL AND METHODS: Sixty implants were inserted in 3D-printed mandibles in 26 different configurations in order to examine the impact of implant diameter, presence of a cover screw, implant design/material, implant position, and the presence of additional implants on implant blooming using two cone-beam computed tomography (CBCT) devices (Accuitomo [ACC] and NewTom [NWT]). Two observers measured the amount of implant blooming in both buccolingual and mesiodistal directions. Inter-rater agreement and descriptive statistics, grouped by implant characteristic and CBCT device, were calculated. RESULTS: Both CBCT devices increased implant diameter (a mean increase of 9.2% and 11.8% for titanium, 20.3% and 24.4% for zirconium, for ACC and NWT, respectively). An increase in implant diameter did not increase the amount of blooming, whereas placing a cover screw did (from 8.0% to 10.9% for ACC, and from 10.0% to 15.6% for NWT). Moreover, implant design, anatomical region, and the presence of another implant also affected the extent of the blooming. CONCLUSIONS: Dental implants show a clear diameter increase on CBCT, with the effect being more pronounced for zirconium than for titanium implants. Similar effects are likely to occur in the clinical setting, potentially masking nonosseointegration, reducing the dimensions of peri-implant defects, and/or causing underestimation of the buccal bone thickness.


Assuntos
Implantes Dentários , Humanos , Titânio
13.
Braz. dent. j ; 33(3): 1-7, July-Sept. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384036

RESUMO

Abstract The present study aimed to compare the filled volume by gutta-percha and sealer in the apical region of the main canal and ramifications, after instrumentation at two different working lengths using nano-computed tomography (nano-CT). Twenty-two premolars with apical ramifications were selected after micro-computed tomography evaluation and were randomly divided into groups for further endodontic instrumentation at two different working lengths: G1 - Root canals shaped 1 mm short of the apical foramen (n=11), and G2 - Root canals shaped at the apical foramen (n=11). After completing root treatment, nano-CT images were acquired, and the filled volume by gutta-percha and sealer in the main canal apical 0-4 mm and 0-1 mm ranges, and apical ramifications were objectively measured by an operator specialized in both radiology and endodontics, blinded for both groups. The Mann-Whitney test was applied to compare both groups regarding the filling of the main canal apical ranges and apical ramifications with a significance level of 5% (α ≤ 0.05). It was observed that root canals shaped at the apical foramen had a larger volume of the main canal filled than root canals shaped 1 mm short of the apical foramen, at both apical ranges (0-4 and 0-1 mm) (p<0.05). Regarding the filling of the apical ramifications, there was no significant difference between groups (p>0.05). In conclusion, the root canals shaped at apical foramen exhibited increased filling volume of the main canal in the apical region. However, neither of both working lengths influenced filling of the apical ramifications.


Resumo O presente estudo teve como objetivo comparar o volume preenchido por guta-percha e cimento na região apical do canal principal e ramificações, após instrumentação em dois comprimentos de trabalho diferentes, por meio de nano tomografia computadorizada (nano-TC). Vinte e dois pré-molares com ramificações apicais foram selecionados após avaliação por micro-tomografia computadorizada e foram divididos aleatoriamente em grupos para posterior instrumentação endodôntica em dois comprimentos de trabalho diferentes: G1 - Canais radiculares instrumentados 1 mm aquém do forame apical (n = 11) e G2 - Canais radiculares instrumentados até o forame apical (n = 11). Após a obturação dos canais radiculares, imagens de nano-CT foram adquiridas, e o volume preenchido por guta-percha e cimento nas faixas apicais de 0-4 mm e 0-1 mm do canal principal, e ramificações apicais, foram avaliadas objetivamente por um especialista em radiologia e endodontia, cego para ambos os grupos. O teste de Mann-Whitney foi aplicado para comparar os dois grupos quanto ao preenchimento das faixas apicais do canal principal e ramificações com nível de significância de 5% (α ≤ 0,05). Observou-se que canais radiculares instrumentados até o forame apical apresentaram maior volume do canal principal preenchido do que canais radiculares instrumentados 1 mm aquém do forame apical, em ambas as faixas apicais (0-4 e 0-1 mm) (p <0,05) Em relação ao preenchimento das ramificações apicais, não houve diferença significativa entre os grupos (p> 0,05). Em conclusão, os canais radiculares instrumentados até o forame apical mostraram um maior volume de preenchimento na região apical do canal principal. No entanto, os dois diferentes comprimentos de trabalho não influenciaram o preenchimento das ramificações apicais.

14.
Braz Dent J ; 33(3): 1-7, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766712

RESUMO

The present study aimed to compare the filled volume by gutta-percha and sealer in the apical region of the main canal and ramifications, after instrumentation at two different working lengths using nano-computed tomography (nano-CT). Twenty-two premolars with apical ramifications were selected after micro-computed tomography evaluation and were randomly divided into groups for further endodontic instrumentation at two different working lengths: G1 - Root canals shaped 1 mm short of the apical foramen (n=11), and G2 - Root canals shaped at the apical foramen (n=11). After completing root treatment, nano-CT images were acquired, and the filled volume by gutta-percha and sealer in the main canal apical 0-4 mm and 0-1 mm ranges, and apical ramifications were objectively measured by an operator specialized in both radiology and endodontics, blinded for both groups. The Mann-Whitney test was applied to compare both groups regarding the filling of the main canal apical ranges and apical ramifications with a significance level of 5% (α ≤ 0.05). It was observed that root canals shaped at the apical foramen had a larger volume of the main canal filled than root canals shaped 1 mm short of the apical foramen, at both apical ranges (0-4 and 0-1 mm) (p<0.05). Regarding the filling of the apical ramifications, there was no significant difference between groups (p>0.05). In conclusion, the root canals shaped at apical foramen exhibited increased filling volume of the main canal in the apical region. However, neither of both working lengths influenced filling of the apical ramifications.


Assuntos
Guta-Percha , Materiais Restauradores do Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular/métodos , Microtomografia por Raio-X
15.
Sci Rep ; 12(1): 7523, 2022 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-35525857

RESUMO

An accurate three-dimensional (3D) segmentation of the maxillary sinus is crucial for multiple diagnostic and treatment applications. Yet, it is challenging and time-consuming when manually performed on a cone-beam computed tomography (CBCT) dataset. Recently, convolutional neural networks (CNNs) have proven to provide excellent performance in the field of 3D image analysis. Hence, this study developed and validated a novel automated CNN-based methodology for the segmentation of maxillary sinus using CBCT images. A dataset of 264 sinuses were acquired from 2 CBCT devices and randomly divided into 3 subsets: training, validation, and testing. A 3D U-Net architecture CNN model was developed and compared to semi-automatic segmentation in terms of time, accuracy, and consistency. The average time was significantly reduced (p-value < 2.2e-16) by automatic segmentation (0.4 min) compared to semi-automatic segmentation (60.8 min). The model accurately identified the segmented region with a dice similarity co-efficient (DSC) of 98.4%. The inter-observer reliability for minor refinement of automatic segmentation showed an excellent DSC of 99.6%. The proposed CNN model provided a time-efficient, precise, and consistent automatic segmentation which could allow an accurate generation of 3D models for diagnosis and virtual treatment planning.


Assuntos
Seio Maxilar , Redes Neurais de Computação , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador , Seio Maxilar/diagnóstico por imagem , Reprodutibilidade dos Testes
16.
Clin Oral Implants Res ; 33(5): 558-567, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35266206

RESUMO

AIM: To validate in vitro the accuracy of a novel method for bone augmentation of horizontal alveolar bone defects with the help of a surgical guide. MATERIAL AND METHODS: Six cone-beam computed tomography scans of patients requiring horizontal bone augmentation were segmented and 3D printed. Two surgeons performed the bone augmentation surgery twice for each case on 3D-printed models, using either a conventional or guided protocol. Each surgeon virtually planned the desired graft shape beforehand. The resulting grafts were compared linearly and volumetrically to the plan; graft density and surgical time were also analyzed. RESULTS: There was significantly less graft volume outside the planned volume with the guided protocol (36.8% ± 14.1 vs. 19.6% ± 12.3, p < .01). The use of a guide increased graft accuracy at several measurement points, resulting in less overfill when using the guided protocol (1.7 ± 1.7 mm at the most coronal point, 0.2 mm ± 1.4 at 25%, 0.0 mm ± 0.9 at 50%, 0.1 mm ± 1.1 at 75%, and 0.4 mm ± 1.4 apically). Graft thickness was increased 1 mm coronally from the planned graft (2.8 mm ± 2.3 vs. 1.8 mm ± 2.2, p = .04). Surgical time increased significantly when using a guide (a difference of 2 m 26 s). CONCLUSION: The technique, tested here in vitro, allows surgeons to improve the accuracy of the resulting graft shape, to better compact material in the coronal portion of the graft, and to reduce the amount of graft material placed outside the planned volume.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Cirurgia Assistida por Computador , Aumento do Rebordo Alveolar/métodos , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Humanos
17.
Restor Dent Endod ; 47(1): e2, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35284328

RESUMO

Objectives: This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements. Materials and Methods: Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) (n = 24). The samples were scanned using micro-CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 µm. Analysis of variance and the Tukey test were conducted, and the degree of agreement between different voxel sizes was evaluated using the Bland and Altman method (p < 0.05). Results: All materials showed an increase in thickness from 5 to 10 and 20 µm (p < 0.05). When evaluating the interface voids, materials were similar at 5 µm (p > 0.05), while at 10 and 20 µm Biodentine showed the lowest percentage of voids (p < 0.05). A decrease in the interface voids was observed for MTA and IRM at 20 µm, while Biodentine showed differences among all voxel sizes (p < 0.05). The Bland-Altman plots for comparisons among voxel sizes showed the largest deviations when comparing images between 5 and 20 µm. Conclusions: Voxel size had an impact on the micro-CT evaluation of thickness and interface voids of endodontic materials. All cements exhibited an increase in thickness and a decrease in the void percentage as the voxel size increased, especially when evaluating images at 20 µm.

18.
Clin Oral Investig ; 26(6): 4457-4466, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35166942

RESUMO

OBJECTIVES: The overall objective of this study was to assess how metal artefacts impact image quality of 13 CBCT devices. As a secondary objective, the influence of scanning protocols and field of view on CBCT image quality with and without metal artefacts was also assessed. MATERIALS AND METHODS: CBCT images were acquired of a dry human skull phantom considering three clinical simulated conditions: one without metal and two with metallic materials (metallic pin and implant). An industrial micro-CT was used as a reference to register the CBCT images. Afterwards, four observers evaluated 306 representative image slices from 13 devices, ranking them from best to worst. Furthermore, within each device, medium FOV and small FOV standard images were compared. General linear mixed models were used to assess subjective perception of examiners on overall image quality in the absence and presence of metal-related artefacts (p < 0.05). RESULTS: Image quality perception significantly differed amongst CBCT devices (p < 0.05). Some devices performed significantly better, independently of scanning protocol and clinical condition. In the presence of metal artefacts, medium FOV standard scanning protocols scored significantly better, while in the absence of metal, small FOV standard yielded the highest performance. CONCLUSIONS: Subjective image quality differs significantly amongst CBCT devices and scanning protocols. Metal-related artefacts may highly impact image quality, with a significant device-dependent variability and only few scanners being more robust against metal artefacts. Often, metal artefact expression may be somewhat reduced by proper protocol selection. CLINICAL RELEVANCE: Metallic objects may severely impact image quality in several CBCT devices.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Metais , Percepção , Imagens de Fantasmas
19.
Clin Oral Investig ; 26(2): 1625-1636, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34424401

RESUMO

OBJECTIVES: This study aimed to describe and compare CBCT imaging prescription in clinical practice among orthodontists from five countries in Europe and America. Additionally, it investigated factors associated with the prescribing and the use of guidelines for CBCT imaging. MATERIALS AND METHODS: A cross-sectional survey was carried out using an online questionnaire sent to all registered orthodontists in Belgium, Brazil, Canada, Romania, and the United States of America (USA). The data were analyzed by descriptive statistics, bivariate tests, and Poisson regression. RESULTS: The final sample consisted of 1284 participants. CBCT was prescribed by 84.4% of the participants for selected cases (84.9%), mainly for impacted teeth (92.4%), presurgical planning (54.1%), and root resorption (51.9%). High cost was most frequently the limiting factor for CBCT prescription (55.4%). Only 45.2% of those who were using CBCT imaging reported adhering to guidelines. CBCT imaging prescription was associated with the orthodontists' countries (p < .009, except for Belgium, p = .068), while the use of guidelines was associated with the respondents' country and additional training on CBCT imaging (p < .001). CONCLUSIONS: Orthodontists refer patients for CBCT for selected indications (impacted teeth, root resorption, presurgical planning, dentofacial deformities, as suggested by the international guidelines, and also for upper airway and temporomandibular joint evaluation). Many do not adhere to specific guidelines. There are substantial variations between the countries about the orthodontists' referral for CBCT and guideline usage, irrespective of gender. CBCT prescription may be limited by financial barriers, adhering to specific guidelines and prior CBCT training. CLINICAL RELEVANCE: CBCT prescription among orthodontists must be based on prescription criteria and current guidelines. It is advised to improve CBCT education and training to enhance CBCT selection, referral, analysis, and interpretation in orthodontic practice.


Assuntos
Ortodontia , Dente Impactado , Tomografia Computadorizada de Feixe Cônico , Estudos Transversais , Humanos , Ortodontistas , Inquéritos e Questionários , Estados Unidos
20.
Aust Endod J ; 48(3): 515-521, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34939718

RESUMO

Apical periodontitis shows radiographic signs such as widening of the periodontal ligament and periapical radiolucency, which differ in extent depending on the stage of the lesion. However, other lesions can be associated with or coincidental to the apical region, representing developmental lesions and benign or malignant tumours. This article describes three cases of malignant tumours, a central mucoepidermoid carcinoma (CMEC), a chondroblast osteosarcoma and an osteosarcoma of the jaw (OSJ) that presented as periapical lesions. Endodontists must be aware of unsuccessful treatment, persistent pain, signs of paraesthesia, a rapid growth rate and delayed response to therapy associated with atypical features. Complementary examinations, such as biopsy and computed tomography, can allow the early diagnosis of malignant tumours, leading to a better prognosis and thus increased survival rates and improvement in quality of life.


Assuntos
Neoplasias Ósseas , Osteossarcoma , Periodontite Periapical , Humanos , Qualidade de Vida , Diagnóstico Diferencial , Periodontite Periapical/diagnóstico por imagem , Osteossarcoma/diagnóstico , Osteossarcoma/patologia , Neoplasias Ósseas/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...